ADR Table A — public information
UN 2202HYDROGEN SELENIDE, ANHYDROUS
Sealed Table A fields for this UN number. This page informs; it does not run a compliance check or consume the free daily check limit.
- Proper shipping name(ADR 3.2)
- HYDROGEN SELENIDE, ANHYDROUS
- Class / classification(ADR 3.2)
- 2 · 2TF
- Packing group(ADR 3.2)
- —
- Labels(ADR 5.2)
- 2.3, +2.1
ADR 3.2 · Tunnel code / Transport category / Limited quantity (LQ) / Excepted quantity (EQ)
- Tunnel code(ADR 8.6.4)
- D
- Transport category(ADR 1.1.3.6)
- 1
- Limited quantity (LQ)(ADR 3.4)
- 0
- Excepted quantity (EQ)(ADR 3.5)
- E0
- Packing instructions(ADR 3.2 (8))
- P200
- Mixed-packing (MP) codes(ADR 4.1.10)
- MP9
Packaging family rulings (K1+K2)
Four packaging families from Table A column (8), with tip lists and special packing provisions (PP/B/L). Absence is a ruling, not silence.
✅ Drums / jerricans / boxes · ALLOWED — Drums / jerricans / boxes route is open — assigned instruction: P200.
P200: no tip-list row in dictionary.
No special packing provision is assigned to this UN. P200 footnotes: k.
▸ Technical basis
Table A column (8): P200 · packing_instructions pin 04607c36 · Tablo A sütun (9b)=[] · special_packing_codes a453254a k [OK] · Valve outlets shall be fitted with pressure retaining gas-tight plugs or caps having threads that match those of the valve outlets and made of material not liable to attack by the contents of the pressure receptacle. Each cylinder within a bundle shall be fitted with an individual valve that shall be closed during carriage. After filling, the manifold shall be evacuated, purged and plugged. Bundles containing UN No. 1045 Fluorine, compressed, may be constructed with isolation valves on groups of cylinders not exceeding 150 litres total water capacity instead of isolation valves on every cylinder. Cylinders and individual cylinders within a bundle shall have a test pressure greater than or equal to 200 bar and a minimum wall thickness of 3.5 mm for aluminium alloy or 2 mm for steel. Individual cylinders not complying with this requirement shall be carried in a rigid outer packaging that will adequately protect the cylinder and its fittings and meeting the packing group I performance level. Pressure drums shall have a minimum wall thickness as specified by the competent authority. Pressure receptacles shall not be fitted with a pressure relief device. Cylinders and individual cylinders in a bundle shall be limited to a maximum water capacity of 85 litres. Each valve shall be capable of withstanding the test pressure of the pressure receptacle and be connected directly to the pressure receptacle by either a taper thread or other means which meets the requirements of ISO 10692-2:2001. Each valve shall either be of the packless type with non-perforated diaphragm, or be of a type which prevents leakage through or past the packing. Carriage in capsules is not allowed. Each pressure receptacle shall be tested for leakage after filling. Gas specific provisions · künye 61099195 P200 footnotes=k · SDS §10 yok TR packaging type names: UAB ADR 2023 TR stamped dictionary
❌ IBC · NOT ALLOWED — No IBC instruction is assigned — may not be carried in IBCs (ADR 4.1.2.1, column (8)).
No family instruction — special packing provisions do not apply.
▸ Technical basis
Table A column (8): — · packing_instructions pin 04607c36 · ADR 4.1.2.1 familyVerdict=UYGUN_DEGIL → question suppressed TR packaging type names: UAB ADR 2023 TR stamped dictionary
❌ Large packaging (LP) · NOT ALLOWED — No large packaging (LP) instruction is assigned — may not be carried in large packaging (LP) (ADR 4.1.2.1, column (8)).
No family instruction — special packing provisions do not apply.
▸ Technical basis
Table A column (8): — · packing_instructions pin 04607c36 · ADR 4.1.2.1 familyVerdict=UYGUN_DEGIL → question suppressed TR packaging type names: UAB ADR 2023 TR stamped dictionary
❌ Light-gauge metal (R001) · NOT ALLOWED — No light-gauge metal packaging (R001) instruction is assigned — may not be carried in light-gauge metal packaging (R001) (ADR 4.1.2.1, column (8)).
No family instruction — special packing provisions do not apply.
▸ Technical basis
Table A column (8): — · packing_instructions pin 04607c36 · ADR 4.1.2.1 familyVerdict=UYGUN_DEGIL → question suppressed TR packaging type names: UAB ADR 2023 TR stamped dictionary
Verify the packaging I have
Enter the UN mark on your package (e.g. 4G/Y145/S/23/…). This checks type against this UN’s packing rules — it does not calculate quantity.
As you type, parts of the mark appear here — this is a guide, not a ruling.
Final ruling only after you press Check mark.
Sea (IMDG 41-22TR)
Sealed Dangerous Goods List fields for this UN when present in IMDG 41-22TR. Concept ⓘ tips are not the legal wording.
IMDG 41-22TR · T.C. UAB yayını Türkçe çeviri — gayriresmî; İngilizce metin esastır
Manifests: DGL 7eab27ec · rules b6a9dc11
Articles: IMDG 3.2 · IMDG 7.1 · IMDG 7.2.5 · IMDG EmS
- Proper shipping name (sea) (IMDG 3.2)
- HYDROGEN SELENIDE, ANHYDROUS
- Class / division (IMDG 3.2)
- 2.3
- EmS(IMDG EmS)
- F-D, S-U
- Stowage category(IMDG 7.1)
- D
- Segregation group(IMDG 7.2.5)
No segregation group is assigned to this substance — pair checks use the general rules.
Need a sealed compliance check?
Run the full road / road+sea check with quantity, mixed loading, points and edition seal.
Full check + seal → /checkInformation only from the sealed ADR Table A dataset. Not a legal certification. Where a check cannot decide, HazSeal answers NEEDS_REVIEW.