UN 1956COMPRESSED GAS, N.O.S.

Sealed Table A fields for this UN number. This page informs; it does not run a compliance check or consume the free daily check limit.

Edition: ADR2025manifest edda6235Articles: 3.2.1 · 3.4 · 3.5 · 1.1.3.6 · 8.6.3 · 8.6.4
Proper shipping name(ADR 3.2)
COMPRESSED GAS, N.O.S.
Class / classification(ADR 3.2)
2 · 1A
Packing group(ADR 3.2)
Labels(ADR 5.2)
2.2
ADR 3.2 · Tunnel code / Transport category / Limited quantity (LQ) / Excepted quantity (EQ)
Tunnel code(ADR 8.6.4)
E
Transport category(ADR 1.1.3.6)
3
Limited quantity (LQ)(ADR 3.4)
120ML
Excepted quantity (EQ)(ADR 3.5)
E1
Packing instructions(ADR 3.2 (8))
P200
Special provisions(ADR 3.3 (9))
274, 378, 392, 655, 662
Mixed-packing (MP) codes(ADR 4.1.10)
MP9

Packaging family rulings (K1+K2)

Four packaging families from Table A column (8), with tip lists and special packing provisions (PP/B/L). Absence is a ruling, not silence.

✅ Drums / jerricans / boxes · ALLOWED — Drums / jerricans / boxes route is open — assigned instruction: P200.

P200: no tip-list row in dictionary.

No special packing provision is assigned to this UN. P200 footnotes: ua · va · z.

Technical basis

Table A column (8): P200 · packing_instructions pin 04607c36 · Tablo A sütun (9b)=[] · special_packing_codes a453254a ua [OK] · The interval between periodic tests may be extended to 15 years for aluminium alloy cylinders and bundles of such cylinders if the provisions of paragraph (13) of this packing instruction are applied. This shall not apply to cylinders made from aluminium alloy AA 6351. For mixtures, this provision "ua" may be applied provided all the individual gases in the mixture have been allocated "ua" in Table 1 or Table 2. · künye 61099195 va [OK] · For seamless steel cylinders which are equipped with residual pressure valves (RPVs) (see note below) that have been designed and tested in accordance with EN ISO 15996:2005 + A1:2007 or EN ISO 15996:2017 and for bundles of seamless steel cylinders equipped with main valve(s) with a residual pressure device, tested in accordance with EN ISO 15996:2005 + A1:2007 or EN ISO 15996:2017, the interval between periodic tests may be extended to 15 years if the provisions of paragraph (13) of this packing instruction are applied. For mixtures, this provision "va" may be applied provided all the individual gases in the mixture have been allocated "va" in Table 1 or Table 2. NOTE: "Residual Pressure Valve" (RPV) means a closure which incorporates a residual pressure device that prevents ingress of contaminants by maintaining a positive differential between the pressure within the cylinder and the valve outlet. In order to prevent back-flow of fluids into the cylinder from a higher pressure source a "Non-Return Valve" (NRV) function shall either be incorporated into the residual pressure device or be a discrete additional device in the cylinder valve, e.g. a regulator. Cont'd on next page Requirements for N.O.S. entries and for mixtures · künye 61099195 z [OK] · The construction materials of the pressure receptacles and their accessories shall be compatible with the contents and shall not react to form harmful or dangerous compounds therewith. The test pressure and filling ratio shall be calculated in accordance with the relevant requirements of (5). Toxic substances with an LC₅₀ less than or equal to 200 ml/m³ shall not be carried in tubes, pressure drums or MEGCs and shall meet the requirements of special packing provision "k". However, UN No. 1975 Nitric oxide and dinitrogen tetroxide mixture may be carried in pressure drums. For pressure receptacles containing pyrophoric gases or flammable mixtures of gases containing more than 1 % pyrophoric compounds, the requirements of special packing provision "q" shall be met. The necessary steps shall be taken to prevent dangerous reactions (i.e. polymerisation or decomposition) during carriage. If necessary, stabilisation or addition of an inhibitor shall be required. Mixtures containing UN No. 1911 diborane, shall be filled to a pressure such that, if complete decomposition of the diborane occurs, two thirds of the test pressure of the pressure receptacle shall not be exceeded. Mixtures containing UN No. 2192 germane, other than mixtures of up to 35 % germane in hydrogen or nitrogen or up to 28 % germane in helium or argon, shall be filled to a pressure such that, if complete decomposition of the germane occurs, two thirds of the test pressure of the pressure receptacle shall not be exceeded. Mixtures of fluorine and nitrogen with a fluorine concentration below 35 % by volume may be filled in pressure receptacles up to a maximum allowable working pressure for which the partial pressure of fluorine does not exceed 3.1 MPa (31 bar) absolute. 31 working pressure (bar) < -1 xf where: xf = fluorine concentration in % by volume/100. Mixtures of fluorine and inert gases with a fluorine concentration below 35 % by volume may be filled in pressure receptacles up to a maximum allowable working pressure for which the partial pressure of fluorine does not exceed 3.1 MPa (31 bar) absolute, additionally taking the coefficient of nitrogen equivalency in accordance with ISO 10156:2017 into account when calculating the partial pressure. 31 working pressure (bar) < (x + Kk × xk ) - 1 xf f where: xf = fluorine concentration in % by volume/100; Kk = coefficient of equivalency of an inert gas relative to nitrogen (coefficient of nitrogen equivalency); xk = inert gas concentration in % by volume/100. However, the working pressure for mixtures of fluorine and inert gases shall not exceed 20 MPa (200 bar). The minimum test pressure of pressure receptacles for mixtures of fluorine and inert gases equals 1.5 times the working pressure or 20 MPa (200 bar), with the greater value to be applied. Requirements for substances not in Class 2 · künye 61099195 P200 footnotes=ua,va,z · SDS §10 yok TR packaging type names: UAB ADR 2023 TR stamped dictionary

❌ IBC · NOT ALLOWED — No IBC instruction is assigned — may not be carried in IBCs (ADR 4.1.2.1, column (8)).

No family instruction — special packing provisions do not apply.

Technical basis

Table A column (8): — · packing_instructions pin 04607c36 · ADR 4.1.2.1 familyVerdict=UYGUN_DEGIL → question suppressed TR packaging type names: UAB ADR 2023 TR stamped dictionary

❌ Large packaging (LP) · NOT ALLOWED — No large packaging (LP) instruction is assigned — may not be carried in large packaging (LP) (ADR 4.1.2.1, column (8)).

No family instruction — special packing provisions do not apply.

Technical basis

Table A column (8): — · packing_instructions pin 04607c36 · ADR 4.1.2.1 familyVerdict=UYGUN_DEGIL → question suppressed TR packaging type names: UAB ADR 2023 TR stamped dictionary

❌ Light-gauge metal (R001) · NOT ALLOWED — No light-gauge metal packaging (R001) instruction is assigned — may not be carried in light-gauge metal packaging (R001) (ADR 4.1.2.1, column (8)).

No family instruction — special packing provisions do not apply.

Technical basis

Table A column (8): — · packing_instructions pin 04607c36 · ADR 4.1.2.1 familyVerdict=UYGUN_DEGIL → question suppressed TR packaging type names: UAB ADR 2023 TR stamped dictionary

Verify the packaging I have

Enter the UN mark on your package (e.g. 4G/Y145/S/23/…). This checks type against this UN’s packing rules — it does not calculate quantity.

As you type, parts of the mark appear here — this is a guide, not a ruling.

Final ruling only after you press Check mark.

Sea (IMDG 41-22TR)

Sealed Dangerous Goods List fields for this UN when present in IMDG 41-22TR. Concept ⓘ tips are not the legal wording.

IMDG 41-22TR · T.C. UAB yayını Türkçe çeviri — gayriresmî; İngilizce metin esastır

Manifests: DGL 7eab27ec · rules b6a9dc11

Articles: IMDG 3.2 · IMDG 7.1 · IMDG 7.2.5 · IMDG EmS

Proper shipping name (sea) (IMDG 3.2)
COMPRESSED GAS, N.O.S.
Class / division (IMDG 3.2)
2.2
EmS(IMDG EmS)
F-C, S-V
Stowage category(IMDG 7.1)
A
Segregation group(IMDG 7.2.5)

No segregation group is assigned to this substance — pair checks use the general rules.

Need a sealed compliance check?

Run the full road / road+sea check with quantity, mixed loading, points and edition seal.

Full check + seal → /check